Device Information
Device Name
Transmission Electron Microscope (TEM)
Model
JEOL JEM-100CX II
Units Available
1
Manufacture Year
Manufacturer Website
Description
This unit contains a transmission electron microscope, which is an advanced microscopic technique that relies on transmitting a beam of electrons through an ultra-thin specimen. The electrons interact with the specimen, forming a high-resolution image that appears on a fluorescent screen and can be captured by a CCD video camera. The microscope has the ability to magnify images up to 800,000 times, providing much greater resolution than optical microscopes due to the shorter wavelength of electrons. This enables the observation of fine structural details. the transmission electron microscope is considered an essential analytical tool used in various scientific fields, including physics, biology, cancer research, and virology. It also plays a significant role in materials science, such as in semiconductor research and nanotechnology applications.
Services & Pricing
Service | Cost |
---|---|
Examination of a biological sample on the transmission electron microscope for 1 hour + 5 images | 350/400 EGP |
carbon grid for nano sample 1 hour + 5 images | 570/630 EGP |
carbon grid for bacterial/viral samples | 630/690 EGP |
1 hour + 5 images | 570/630 EGP |
Preparation and sectioning of the biological sample | 100/120 EGP |
Preparation of 100 ml glutaraldehyde solution for fixation | 85/115 EGP |
Additional semi-thin sectioning of a biological sample (prepared inside the lab) | 170/200 EGP |
Additional ultrathin sectioning of a biological sample (prepared inside the lab) | 115/145 EGP |
Additional semi-thin sectioning of a biological sample (prepared outside the lab) | 200/230 EGP |
Additional ultrathin sectioning of a biological sample (prepared outside the lab) | 170/170 EGP |
Re-examination on the transmission electron microscope for 30 minutes + 5 images | 40/50 EGP |
Taking extra images for any sample on the microscope (per image) | 40/50 EGP |